Sun Fire V480 specifications:

Processors:

Number: Up to two dual-processor CPU/Memory Boards (2 or 4 CPUs)

Architecture: 900-MHz, 1050-MHz, or 1200-MHz UltraSPARC III Cu

X7028A - CPU/Memory Board w/ 2× US III Cu 900MHz, 4GB Memory

X6894A - CPU/Memory Board w/ 2× US III Cu 1050MHz, 4GB Memory

X6895A - CPU/Memory Board w/ 2× US III CU 1200MHz, 4GB Memory 

X7272A - CPU/Memory Board w/ 2× US III CU 1200MHz, 8GB Memory 

X7047A - CPU/Memory Board w/ 2× US III 750MHz, 4GB Memory

Cache Memory: 64-KB data and 32-KB instruction 

Secondary: 8-MB external

501-5819 - Sun Microsystems Sun Fire V480 Centerplane - Motherboard

501-5820 - Sun Microsystems Sun Fire V480 PCI I/O Riser Board

Sun Fire V480 Main Memory

Capacities: 8 memory slots (DIMMs) per processor, 16 total slots per CPU/Memory Board 

256-MB, 512-MB, or 1-GB expansion (16GB maximum per CPU/Memory board, 32GB maximum when configured with 4 processors) 

X7051A - 2GB Memory Kit

X7053A - 1GB Memory Kit

X7056A - 4GB Memory Kit 

X7056A-Z - 4GB Memory kit 

501-5030 - 512MB SDRAM DIMM 

540-5086 - 1GB SDRAM DIMM

Note: Install DIMMs in groups of four. 1050MHz CPU/Memory boards require that all memory DIMM slots be fully populated.

Sun Fire V480 Standard Interfaces

Ethernet: Two 10/100/1000BASE-T twisted-pair ethernet ports ( RJ-45) 

X4444A - Quad GigaSwift Ethernet UTP (QGE)

X1033A - Sun FastEthernet PCI Adapter (FE/P) 2.0

X1034A - Quad FastEthernet PCI (QFE/P)

X1141A - Gigabit Ethernet PCI (GBE/P) 2.0

X1150A - Sun GigaSwift Ethernet UTP (Copper)

X1151A - Sun GigaSwift Ethernet MMF (Fiber)

X3150A - Sun GigaSwift Ethernet UTP (Copper)

X3151A - Sun GigaSwift Ethernet MMF (Fiber)

X4150A - GigaSwift Ethernet UTP (GCS)

X4151A - GigaSwift Ethernet MMF (GFS)

X5544A-4 - 10Gb PCI-X Ethernet Adapter, no transceiver

X5558A - XFP Optical Transceiver Multi Mode Fibre 

X5559A - XFP Optical Transceiver Single Mode Fibre

FC-AL: One Fibre Channel Arbitrated Loop (FC-AL) high-speed serial data connector (HSSDC) 

SG-XPCI1FC-EM2 - 2Gb PCI-X Single FC Host Adapter

SG-XPCI1FC-QF4 - 4Gb PCI-X Single FC Host Adapter 

SG-XPCI1FC-QL2 - 2Gb PCI-X Single FC Host Adapter 

SG-XPCI2FC-EM2 - 2Gb PCI-X Dual FC Host Adapter 

SG-XPCI2FC-QF2-Z - 2Gb PCI Dual FC Host Adapter 

SG-XPCI2FC-QF4 - 4Gb PCI-X Dual FC Host Adapter 

X6727A - PCI Dual FC Host Adapter+

SG-XPCI1FC-QF2 - 2Gb PCI Single FC Host Adapter 

SG-XPCI2FC-QF2 - 2Gb PCI Dual FC Host Adapter 

X6767A - 2Gb PCI Single FC Host Adapter

X6768A - 2Gb PCI Dual FC Host Adapter 

X6799A - PCI Single FC Host Adapter

Keyboard and mouse: USB

PCI: Six PCI slots compliant with PCI specification Revision 2.1:

Two slots operating at 66-MHz, 64 bits wide, 3.3 volts (full length slots)

One slot operating at 33-MHz, 64 bits wide, 5 volts (full-length slot)

Three slots operating at 33-MHz, 64 bits wide, 5 volts (short slot)

Remote System Controller: One RSC card plugs into a dedicated slot on the system I/O board which includes integrated modem, serial and Ethernet interfaces.

One 56 Kbps modem port (RJ-11)

One EIA-232D serial port (RJ-45)

One 10 Mbps Ethernet port (RJ-45)

Serial: One RJ45 serial port

USB: Two standard Universal Serial Bus(USB) Type A connectors

Sun Fire V480 Internal Mass Storage

Disks: Two front-accessible, hot-swappable, FC-AL disks, 36-GB, 73-GB or 146-GB, 3.5-in. x 1.0-in. 10,000 RPM 

X6805A - 73.4GB FC-AL 10000 RPM

XRA-FC1CB-146G10K - 146GB 10000 RPM 

X6724A - 36.4GB FC-AL 10000 RPM

DVD-ROM: 8x DVD-ROM (IDE) drive

Sun Fire V480 Power Supplies

Type: One required, two for N+1 redundancy, each with independent power cord

Output: 560 W per power supply 

300-1480 - Sun Microsystems Sun Fire V480 1184 Watt Power Supply. Tyco A157

375-3006 - Sun Microsystems Sun Fire V480 DC Power Distribution Board

Sun Fire V480 Enviornment

AC input: 100 - 240 VAC, 50 - 60 Hz, 8.6 A(max)

Input power: 1100 W (max)

Heat Output: Base Configuration: 1,634 BTU/hr 

Maximum Configuration: 2,619 BTU/hr 

Temperature: Operating: 5° C to 35° C (41° F to 95° F) 

Nonoperating: -20° C to 60° C (-4° F to 140° F)

Humidity: Operating: 20%to 80% relative temperature humidity, noncondensing 

Nonoperating: 5% to 95% relative temperature humidity, noncondensing

Altitude: Operating: 3000 m (10,000 ft.) 

Nonoperating: 12,000 m (40,000 ft.)

Acoustic noise: Operating: 67 dB(A) 

Idling: 67 dB(A)

Vibration: Operating: .0002 G/Hz, 5 - 500 Hz (random) (deskside)

.0001 G/Hz, 5-150 Hz, -12db/octave slope 150-500 Hz (z-axis only) (rackmounted) 

Nonperating: .002 G/Hz, 5 - 500 Hz (random) (deskside) 

.001 G/Hz, 5-150 Hz, -12db/octave slope 150-500 Hz (z-axis only) (rackmounted)

Shock: Operating: 4G peak, 11 milliseconds half-sine pulse (deskside) 

3G peak, 11 milliseconds half-sine pulse (rackmounted) 

Nonoperating: 15G peak, 11 milliseconds half-sine pulse (deskside) 

10G peak, 11 milliseconds half-sine pulse (rackmounted)

Number of cords: 2 (max)

Plug Type-U.S.: NEMA 5-15P

Sun Fire V480 Regulations :(meets or exceeds the following requirements)

Safety: UL 60950, CSA C22.2 EN 60950 (from U.L.), TUV 60950, UL CB scheme IEC 950 (CE mark), GOST

RFI/EMI: Class A:Australia/New Zealand AS/NZ 3548, Industry Canada ICES-003, European Community EN55022/CISPR22, Japan VCCI, Taiwan CNS 13438, and US FCC 47CFR15.B

Immunity: EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, IEC 61000-3-2, and IEC 61000-3-3

X-ray: U..DHHS 21CFR Subchapter J,PTB German X-ray Decree

Sun Fire V480 Dimensions and Weights

Height: 22.2 cm (8.75 in.), 5 Rack Units

Width: 44.6 cm (17.5 in.)

Depth: 61.0 cm (24.0 in.)

Weight: 35.8 kg (79 lb.) (minimum) 

44 kg (97 lb.) (fully configured)

Power Cord: 2.5 m (8.2 ft)

Sun Fire V480 Clearance and Service Access

Front: 36 in.

Rear: 36 in.

Sun Fire V480 Rack mounting

Fits into a standard 19-inch-wide rack mount kit that complies with EIA-310-D-1992 standard, or a 72-inch height Sun StorEdge rack, which will support seven Sun Fire V480 servers.

A 72-inch Sun StorEdge rack can physically hold up to seven Sun Fire V480 servers (with a power sequencer there are 36 rack units of usable space and the Sun Fire V480 is 5 rack units high). A Sun Fire V480 with a four-way standard configuration running Sun Virtual Test Suite (VTS) may vary from 750 Watts to 900 Watts depending on the PCI cards installed. The power sequencer in the StorEdge rack provides ~5400 W.

So, a Sun StorEdge rack can support seven Sun Fire V480 servers if they are not fully loaded (if the configurations are only two-way or the PCI slots are not fully populated on a four-way configuration). However, a Sun StorEdge rack can support only six Sun Fire V480 servers if they are fully loaded (four-way configurations and/or full PCI slots) and running a typical workload, like Sun VTS. 

SG-XARY030A - Sun Microsystems 72-inch StorEdge Expansion cabinet

 

Sun Fire V480 server on Rent  Bangalore, Chennai, Hyderabad, Delhi, Pune, Mumbai.