Sun Netra T 1400 Server  specifications:

Racking

Fits into 19-, 23-, 24-in., 600-mm racks (requires mounting kit,19-in.flanges supplied with product, others available as options)

Sun Netra T 1400 Server Processor

Number

Up to four

Architecture

440-MHz, 64-bit, UltraSPARC II

Cache memory

16 KB data and 16 KB instruction on chip

Secondary: 4 MB external (per CPU module)

Main Memory

Capacities

Total of 16 DIMM memory slots available

Up to 4 GB (DIMMS must be installed in sets of four)

Sun Netra T 1400 Server Standard Interfaces

Alarm card

One alarm port (DB15) with relay connections for for Ethernet, ATM, and serial I/O One RS-232/RS-423 asynchronous LOM port (RJ-45)

Ethernet

One ethernet/fast ethernet (10BASE-T/100BASE-T) shielded twisted-pair port (RJ-45)

Keyboard and mouse

One standard keyboard/mouse port (mini DIN-8 ) (this is not an NEBS compliant port)

Parallel

One Centronics-compatible parallel port (DB25); ECP mode capable

PCI

Four full-size PCI 2.1 compliant slots:

Slot 1: 64-bit, 33- or 66-MHz, 5.0/3.3 V

Slots 2 & 3: 32- or 64-bit, 33-MHz, 5.0/3.3 V

Slot 4: 32-bit, 33-MHz, 5.0/3.3 V

SCSI

One 40-MB/sec, 68-pin, UltraSCSI (SCSI-3) port

Serial

Two RS-232/RS-423 asynchronous/synchronous serial ports (DB25)

SCSI

40-MB/sec.Ultra SCSI

Sun Netra T 1400 Server Internal Mass Storage

Disks

Up to four 18-or 36-GB disks

CD-ROM/DVD-ROM

Optional SunCD 32

Optional 10X-speed DVD-ROM, equivalent to 40X-speed CD-ROM

Tape

Optional 12-to 24-GB DDS3, 4 mm

Sun Netra T 1400 Server Power Supply

AC power (Netra t 1405)

Three (n +1 redundant) AC power supplies 100/240 V AC nominal,330 W,dual input

DC power (Netra t 1400)

Three (n +1 redundant) DC power supplies 48/60 V DC nominal,330 W,dual input

Sun Netra T 1400 Server Environment

AC input

90 - 264 VAC, 47 - 63 Hz, 4 A, 0.4 KVA

DC input

-48 to -60 VDC, 10 A @ -48 VDC, 12 A @ -60 VDC

Heat output

2254 BTU/hr

Sun Netra T 1400 Server Temperature*

Operating: 5° C to 40° C (41° F to 104° F)

Operating (short term): -5° C to 55° C (23° F to 131° F)

Nonoperating: -40° C to 70° C (-40° F to 158° F)

Humidity

Operating: 5% to 85% relative humidity, noncondensing

Nonoperating: 10% to 95% relative humidity, noncondensing

Altitude

Operating: -300 m to 3000 m (-1000 ft. to 10,000 ft.)

Nonoperating: -300 m to 12,000 m (-1000 ft. to 40,000 ft.)

ETSI

ETS 300-19-2-3

Acoustic noise

Operating: less than 60dBA

Idling: less than 60dBA

Seismic

Meets GR-63-CORE requirements for earthquake risk zone 4 Meets ETS 300-19-2-3, A1 operating requirements

Number of cords 3

*Short term is defined as no more than 96 hours duration at extremes and at elevations less than 1800m.

Sun Netra T 1400 Server Regulations

Meets or exceeds the following requirements:

Safety

UL 1950/CSA C22.2 No.950, EN 60950 (73/23/EEC), IEC 950

Emissions

CFR Title 47 FCC Part 15, EN 55022 (89/336/EEC), (EN61000-3-2, Netra t 1405 only), Low Voltage Directive (73/23/EEC), CE Mark (93/68/EEC)

Immunity

Directive (73/23/EEC), CE Mark (93/68/EEC)

Certification

Safety: cULus Mark, GS Mark (Netra t 1405 only), CE Mark, Bauart Mark (Netra t 1400 only) EMC CE Mark (93/68/EEC), FCC authorized Class A

Sun Netra T 1400 Server Dimensions and Weights

Height

26.4 cm (10.4 in./6U)

Width

43.18 cm (17 in.)

Depth

50.47 cm (19.9 in.)

Weight