SUN Ultra 5 Workstation on rent Bangalore, Chennai, Hyderabad, Delhi, Pune, Mumbai.

´╗┐Ultra 5 workstation specifications:

Processor

Architecture

270, 333, 360, or 400-MHz UltraSPARC[tm]-IIi

Cache Memory

16-KB instruction cache, 16-KB data cache

256-KB external for 270-MHz and 360-MHz processors

2 MB external for 333-MHz and 400-MHz processors

SUN Ultra 5 Workstation Main Memory

Capacities

Four DIMM slots

Install DIMMs in pairs (16 MB, 32 MB, 64 MB, and 128 MB DIMMs); quad provides best performance

512 MB maximum

Memory type

50ns 168-pin JEDEC DIMMs, ECC error-correction

Standard Interfaces

Audio

Four audio ports: headphone(out), line-in, line-out and microphone(in) using EIA standard 0.125-inch (3.5-mm) jacks

Ethernet

One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45), self-sensing

Graphics

One graphics port (HD15), onboard 8- or 24-bit frame buffer

Keyboard and mouse

One standard keyboard/mouse port (mini DIN-8)

Parallel

One IEEE 1284 (bidirectional) parallel port (DB25)

PCI

Three 32-bit PCI slots, two full-size, one short, 33 MHz, 5 volt

Serial

One synchronous/asynchronous serial port (DB25); one asynchronous serial port (DB9)

SUN Ultra 5 Workstation Internal Mass Storage

Disks

One 4.3/8.4 GB (5400 rpm) or 9.1/20.4 GB (7200 rpm), 3.5- in. Enhanced IDE HDD

Note: You can install a second disk if you remove the floppy and use the PCMCIA drive bay.

Floppy

One 3.5-in. 1.44-MB floppy

CD-ROM

One 24X-, 32X-, or 48X-speed CD-ROM

PCMCIA

One front-access bay for third-party options

SUN Ultra 5 Workstation Environment

AC input

90 - 132 VAC or 180 - 264 VAC (switch selectable), 47 - 63 Hz, 3 A (max), 0.3 KVA

Input Power

286 Watts

Heat output

976 BTU/hr

SUN Ultra 5 Workstation Temperature

Operating: 5° C to 35° C (41° F to 95° F)

Nonoperating: -20° C to 60° C (?4° F to 140° F)

Humidity

Operating: 40% to 80% relative humidity, noncondensing

Nonoperating: 30% to 90% relative humidity, noncondensing

SUN Ultra 5 Workstation Altitude

Operating: 3000 m (10,000 ft)

Nonoperating: 12,000 m (40,000 ft)

Acoustic noise

Operating: 5.2 bels

Idling: 5.1 bels

Number of cords 1

SUN Ultra 5 Workstation Regulations

Meets or exceeds the following requirements:

Safety

UL 1950, CSA C22.2 No. 950, TUV EN 60950, CB Scheme with Nordic deviations, EMKO-TSE(74-SEC) 203, ZH1/618

RFI/EMI

FCC Class B, DOC Class B, VCCI Class 2, EN 55022 Class B, EN 61000-3-2

Immunity

EN 50082-1

X-ray

DHHS 21 Subchapter J; PTB German X-ray Decree

Power management

Energy Star compliant

SUN Ultra 5 Workstation Environment

Power supply

1000 watts

Operating temperature

5°C to 35°C at 3000 meters

Nonoperating temperature

-40°C to 60°C at 12000 meters

SUN Ultra 5 Workstation Dimensions and Weights

Height

11.2 cm (4.4 in.)

Width

43.6 cm (17.1 in.)

Depth

43.0 cm (16.9 in.)

Weight

SUN Ultra 5 Workstation on rent Bangalore, Chennai, Hyderabad, Delhi, Pune, Mumbai.